Find Mag Flow Meter, Flow Meter, Electromagnetic Flow Meter on Industry Directory, Reliable Manufacturer/Supplier/Factory from China.

Inquiry Basket (0)
Home > Products > Flow Meter > Electromagnetic Flow Meter (DN15~2400)

Electromagnetic Flow Meter (DN15~2400)

Basic Info

Model No.:  MAGYN

Product Description

Model NO.: MAGYN Main Application: Water, Diesel Fuel, Fuel Oil Sensor: Tube/Flange Measuring Media: Liquid Trademark: Holley & OEM Origin: Hangzhou Accuracy: ±0.2-0.5% Size: > DN500 Type: Electromagnetic Flow Meter Measuring Principle: Electrical Principles Specification: ISO9001: 2008 HS Code: 90261000 MAGYN Serials Intelligence Electromagnetic Flowmeter
 
General
MAGYN Serials Intelligence Electromagnetic Flowmeter conducts measurement based on the principle of the Faraday Electromagnetic Induction Law. When conductive liquid flows in a magnetic field and incises the magnetic flux, Induced electromotive force E will be generrated in the conductor, as flollow.

Feature And Usage

Independence: When the temperature, pressure, viscosity and density of the measured     
fluid changing, the flowmeter will not be influenced.

Easy Maintenance: No moving parts in measuring tube, so easy maintenance.

Wide Application: Can measure conductivity liquid, Without reference to fibre,solid or suspending material contained in liquid.

Easy Installation: Install any angle only need liquid full of the pipe. Straight pipe 
  requires 5D for upper stream and 2D for down stream

Turndown Ratio: The turndown ratio can reach to 1:100

Enclosure: For DN15~DN1200 is IP68

High Intelligence: Back light English/Chinese LCD display, Menu setting control, three   
  grades password protection, Two-way measuring available, slight signal removal, Auto flow 
  compensation and other function.

SMT Technical:Intelligence self-detect and self-diagnoses, many kinds of alarming
SMART Excitation:Low power consumer, zero stability, longtime reliability
Multi-Signal Output:4~20mA or 0~10mA current output, Standard Pulse Output,
  RS485 computer communication output
Selecting the right lining and electrode material can measure nearly all conductive liquid.
The power supply system has good voltage vibration adaptability.
 
 
 
Main Technical Datum
 
Accuracy:0.3%, 0.5% and1.0%           
Repeatability:0.15%, 0.25% and 0.5%
Ambient Temperature: Sensor (Separate Type):-20°C~+70°C
Converter:-20°C~+50°C    
 Integral type: -10°C-+50°C              
Humidity:5% ~95%RH(No Frost)   
Vibration:Frequecy:55Hz               
Amplitude:0.55mm
Ambient magnetic field:≤400A/m      
 Fluid Temperature:Integral Type  ≤+80°C
Separate Type(Rubber Lining)≤+80°C    (PTFE Lining) ≤+120°C
Nominal Pressure:0.6MPa~32.0MPa       Liquid Conductivity:≥5u/cm
Power Supply:DC24V±5% or  100-240VAC  47~63Hz
Enclosure: IP68(For separate type with synthetic rubber lining only)
Output Signal:4~20mA/0~10mA, Standard Pulse output
Communication:RS485 Computer Interface and HART Protocol
Alarm Output:Alive

Electrode Material:Stainless Steel, Hastelloy, Titanium, Tantalum,
Carbonized Tungsten, platiniridium
Lining Material:PTFE, Synthetic Rubber
Flange Material:Cast Steel and Stainless Steel
Measuring Tube:Stainless Steel
Anti-explosion Grade:ExdeiaIICT4, Anti-explosion No.:GYB03542
Flange Standard:Any Flange Standard can be custom-made.
Electromagnetic Flow Meter (DN15~2400)

Electromagnetic Flow Meter (DN15~2400)

Contact us if you need more details on Flow Meter. We are ready to answer your questions on packaging, logistics, certification or any other aspects about Water Flow Meter、Electromagnetic Flow Meter. If these products fail to match your need, please contact us and we would like to provide relevant information.

Product Categories : Flow Meter